Skip to content
LabExportsLabExports home
HPLC - Engineering Teaching Lab Apparatus scientific laboratory equipment
Engineering Teaching Lab Apparatus

HPLC

An HPLC system has its prime objective to separate, identify, and quantify particular compounds in a mixture.

Price Structure
Direct factory wholesale on request by volume
Tender Documentation
Compliance sheets, BoQ & MAF authorization
Quality Standards
ISO 9001:2015 certified manufacture & CE conformity

Product Specifications & Overview


We are a leading HPLC manufacturer and supplier across the world.

HPLC manufacturers create a specific set of equipment that, when integrated, creates an HPLC system. An HPLC system has its prime objective to separate, identify, and quantify particular compounds in a mixture. The following mixtures are separated, identified, and quantified by HPLC Systems without any pre-treatment:

  • Blood Plasma Proteins

  • Plant Pigments

  • Simple Sugars

  • Organic Acids

  • Nucleotides

  • Pharmaceutical Drugs (small molecules)

  • Vitamins (water-soluble)

  • Fungal Metabolites

  • Environmental Pollutants (small molecules)

  • Food Additives (certain types)

HPLC Systems With Top HPLC Manufacturer, LabExports

HPLC is not the equipment but a system where specific core and secondary equipment work together on certain mixtures to identify, separate, and quantify compounds of a particular mixture. The most trusted HPLC manufacturers manufacture these primary and secondary equipment to create robust HPLC systems. It includes:

Here are the main ones:

  • High-Pressure Pump

  • Injectors (loop injectors and syringe pumps)

  • Column (heart of the HPLC system)

  • Detector (standard detectors include UV/Vis detectors, refractive index detectors, and mass spectrometers)

  • Data Acquisition System (display chromatograms (separation profiles) and perform calculations for quantification) 

In addition to these primary components, some HPLC systems include:

  • Degasser

  • Column Oven

  • Fraction Collector

Top HPLC suppliers also supply these additional components to enhance the functionality and versatility of the HPLC system for specific applications.

Salient Features Of The Equipment That Make HPLC Systems

High-Pressure Pump

  • Flow Rate: Typically ranges from 0.1 mL/min to 10 mL/min, with some high-performance models reaching even higher flow rates.

  • Pressure Limit: It depends on the model but commonly ranges from 40 MPa (6,000 psi) to 100 MPa (14,500 psi) to handle high-pressure mobile phases.

Injector

  • Injection Volume: Usually between 1 µL and 100 µL, depending on the injector type and sample concentration.

  • Reproducibility: Ideally, +/- 1% or better for accurate and consistent sample introduction.

Column

  • Length:  Common ranges are 50 mm to 250 mm for analytical columns and longer for preparative HPLC.

  • Diameter: Typically between 2.1 mm and 4.6 mm for analytical columns. 

Detector

  • Sensitivity: It varies with the type of detector. For instance, the sensitivity of UV/Vis detectors varies according to the wavelength used. 

Data Acquisition System

  • Sampling Rate: The latest models have higher sampling rates that capture fast-eluting peaks with better detail. (e.g., 10 Hz to 100 Hz)

  • These are general ranges, and specific features will vary depending on the model and intended use of the HPLC system.


Technical Specifications & Manufacturing Details

Product LineHPLC
DisciplineEngineering Teaching Lab Apparatus
Manufacturing StandardISO 9001:2015 Quality Management System / CE Marking
Material GradeHeavy-duty institutional grade, corrosion-resistant finish, laboratory safe
Export PackagingFumigated sea-worthy wooden crates with shock absorbent internal buffering (ISPM-15)
Inspection & VerificationFactory pre-dispatch inspection certificate included; third-party SGS / Bureau Veritas supported
Procurement TargetUniversities, Technical Colleges, Secondary Schools, Research Institutes & Government Tenders

Institutional Tender & Global Export Support

Turnkey Tender Paperwork

We provide itemized technical compliance schedules, bid security documentation assistance, manufacturer authorizations (MAF), and warranty compliance letters for public tenders.

International Logistics & Incoterms

Export shipping arranged under FOB, CIF, or CFR terms via major Indian sea ports (Nhava Sheva / Mundra) and air cargo hubs. Full bill of lading and export customs clearance provided.

Frequently Asked Questions

How do I request a quotation for HPLC?

Click 'Request a Quote' or 'Add to Quote' on this page, specify your target quantity and delivery country, or email info@labexports.com. Our export team responds within 24 business hours with an official Proforma Invoice.

Does LabExports provide tender documentation and compliance sheets?

Yes. We provide complete technical compliance sheets, Bill of Quantities (BoQ) support, ISO 9001:2015 certificates, and manufacturer authorization letters (MAF) for government, university, and Ministry of Education procurement tenders.

What are the export packaging and shipping standards?

Every item is packed in export-grade, fumigated, multi-ply sea/air-worthy wooden cases with shock-absorbing foam lining and waterproof barriers adhering to international ISPM-15 phytosanitary standards.

Can third-party pre-shipment inspections (e.g. SGS, Bureau Veritas) be arranged?

Yes. We routinely facilitate pre-shipment quality and quantity inspections by SGS, Bureau Veritas, Intertek, or any nominated third-party inspection agency before dispatch.

More in Engineering Teaching Lab Apparatus