Skip to content
LabExports home
Boiling Heat Transfer Unit Apparatus
Fundamentals of Thermodynamics

Boiling Heat Transfer Unit Apparatus

Boiling Heat Transfer Unit Apparatus: evaporation on a fire tube; evaporation with heating element; transparent process tank; copper piping; CFC free…

Price
On request, by quantity and destination
Tender documents
Specification sheet and quotation on request

Product details


  1. Evaporation on a fire tube
  2. Evaporation with heating element
  3. Transparent process tank
  4. Copper piping
  5. CFC free evaporation liquid
  6. Safety valve
  7. Pressure switch for additional protection of heating circuit, adjustable
  8. Digital displays for measured values

Technical Data

Heater
  • Power: 250W, continuously adjustable
  • Surface area: 0,001875m²
Cooler, copper coil
  1. Diameter: 80mm
  2. Surface area: 0,0578m²
  3. Safety valve opens at 2,2bar
  4. Tank: 2,85L
Measuring Ranges
  1. Pressure: 0...4bar absolute
  2. Power: 0...300W
  3. Flow rate: 0,05...1,8L/min
  4. Temperature thermocouple: 0...200°C
  5. 1x temperature: -5...105°C
  6. 3x temperature: 0...130°C

More in Fundamentals of Thermodynamics